Safety performance and characteristics
1. Adoption of the center axial diode
2. Shell has a high strength anti-aging, UV-resistant ability
3. the use of full potting method, sealing performance through the IP68 test
4. meet the harsh outdoor environmental conditions under the use of demand
5. Higher cost-effective, more stable performance
Technical Parameters
Test standard | IEC62790/UL3730 |
Rated voltage | IEC1500V/UL1500V |
Rated current | 25A |
Cable size | 4 mm² / 12AWG |
Rated reverse current | 47.5A |
Safety Class | Class II |
Temperature range | -40~+85° |
Sink bandwidth | ≤8mm |
Protection grade | IP68 |
Flame retardant grade | 5VB |
Potting gel usage | 25ml |
Number of diodes | 6 |
Electrical Connection | Tin soldering |
Manager Deng:136 5032 3572
Manager Yang:136 5032 3579
Mail:yx2@dianlink.com / yx3@dianlink.com